网站首页期刊介绍通知公告编 委 会投稿须知电子期刊广告合作联系我们
最新消息:
自制女性体内输尿管支架导丝取出器的临床应用研究
作者:梁清  王阔兴  姜波  董秉政  韩从辉  吴天麟 
单位:东南大学医学院附属徐州医院 泌尿外科, 江苏 徐州 221009
关键词:双"J"管 输尿管 取出器 
分类号:R696.1
出版年·卷·期(页码):2009·28·第一期(3-5)
摘要:

目的: 探讨成年女性患者体内留置双"J"管经尿道取出的简便途径。方法: 采用自制的女性体内输尿管支架导丝取出器(专利号:ZL200620075879.7),经尿道拔除20例成年女性患者输尿管内留置的双"J"管(22根)。结果: 21根双"J"管一次性顺利拔出(95.45%),1根经膀胱镜下拔除。结论: 应用自制的取出器经女性尿道拔除双"J"管,方法简便安全、经济有效,值得推广应用。

Objective To explore an easy method of transurethral pulling out double-J stent detained in the adult female.Method Twenty-two indwelling ureter double-J stent (Appl:200620075879.7) were pulled out by self-designed female ureter double-J stent dislodger in twenty female patients.Result Twenty-one indwelling ureter double-J stent were pulled out in 20 female patients(95.45%),and one was pulled out under cystoscope.Conclusion The method of transurethral pulling out female ureter double-J stent placed in bladder by the self-designed dislodger is easy,safe,economic and worthy to be popularized in clinic.

参考文献:

[1] 韩见知,庄乾元.实用腔内泌尿外科学[M].广州:广东科技出版社,2001:309-320.
[2] 李为兵,李龙坤,郡俊安,等.双J管在泌尿外科中的应用(附1 580例报告) [J].中国内镜杂志,2006,(4):376-377.
[3] DU WL,WANGP,HOU XL,et al.Aplication of ureteroscope treating of urethra stenosis in cavity[J].China J Endoscopy,2004,10(1):108.
[4] PAICK S H,PARK H K,OH S J,et al.Characteristics of bacterial colonization and urinary tract infection after indwelling of double-J ureteral stent[J].Urology,2003,62(2):214-217.
[5] 吕建军.经女性尿道钳取法拔除输尿管内双J 管的临床应用[J].实用全科医学,2005,3(6):105-106.
[6] 窦孝康.直钳取出女性双J管60例报告[J].中国全科医学,2007,10(7):835.
[7] 张胜.女性双J管两种拔取方法的临床分析[J].现代泌尿外科杂志,2005,10(1):42.
[8] 王枫钊,汪建平,龚新环,等.B超引导下磁性尿道探条吸出磁性双J管的应用[J].上海医学影像杂志,2003,12(2):140-141.